8/5/2023 0 Comments Trestle scaffolding definitionAll suspension scaffold support devices, such as outrigger beams, cornice hooks, and parapet clamps, must:.Or 2 times the stall load of the hoist.Each suspension rope, including connecting hardware, must be capable of supporting, without failure, at least 6 times the maximum intended load applied to that rope while the scaffold is operating at the greater of either :.Scaffolds and scaffold components must be capable of supporting, without failure, their own weight and at least 4 times their maximum intended load.įoreman Dies When Overloaded Scaffold Falls Counterweights must not be removed from an outrigger beam until the scaffold is disassembled.Counterweights must be secured by mechanical means to the outrigger beams (Figures 2 & 3) to prevent accidental displacement.Counterweights must not be made of flowable materials such as sand, gravel, and similar materials that can be easily dislocated.Masonry units, rolls of roofing felt, and other similar construction materials shall not be used as counterweights.Only items specifically designed as counterweights may be used to counterweight scaffold systems.Or a minimum of 1½ times the tipping moment imposed by the scaffold when it is operating at the stall load of the hoist, whichever is greater.At least 4 times the tipping moment imposed by the scaffold when it is operating at the rated load of the hoist.Counterweights used to balance adjustable suspension scaffolds must be capable of resisting :.Or bolts or other direct connections to the floor or deck.Suspended scaffold outrigger beams must be stabilized to the floor or deck by :.Electrical, chemical or biological hazardsĮdge protection should be installed in accordance with the manufacturer’s instructions.Inadequate Counterweights Cause Two Deaths.Impalement hazards such as exposed reo, pipes, bars and similar.Weak, friable or non-trafficable surfaces.a fall from the platform would be reasonably likely to cause injury.Įxamples include erecting the scaffold adjacent to:.Edge protection is also required for platforms below 2m if the scaffold is erected next to a hazard that means: a risk assessment has determined a fall from the platform is not reasonably likely to cause injury.Įdge protection is required on trestle ladders scaffolds where the platform height exceeds 2m above the supporting surface.if such use is allowed by the manufacturer, and.If a trestle ladder scaffolding system is designed to incorporate edge protection it should only be omitted:
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |